Microsoft ole db service components class not registered excel




















Pipeline]: One or more component failed validation. Error at Data Flow Task 1: There were errors during task validation. VsIntegration I googled that and changed Run64bitRuntime to False, yet problem still exist Anyone know how to fix that??

Improve this question. Hadi Add a comment. Active Oldest Votes. Improve this answer. Hadi Hadi Might as well keep both the 64 and 32 bit files locally if you have to do this a lot. Because you'll end up uninstalling and reinstalling them. Trust me from experience on this one. I have installed the Access Database Engine bit bit still the same issue, I cant install the 32 bit one I am getting that my office is 64 bit so i have to uninstall my office first.

Collectives on Stack Overflow. Learn more. If the bit driver is not installed, run the package in bit mode Ask Question. Asked 10 months ago. Active 10 months ago. Viewed 2k times. If the bit driver is not installed, run the package in bit mode.

How can I fix this error? Thank you. Improve this question. Add a comment. Therefore, if you are not severely affected by this problem, we recommend that you wait for the next software update that contains this hotfix. If the hotfix is available for download, there is a "Hotfix download available" section at the top of this Knowledge Base article. If this section does not appear, contact Microsoft Customer Service and Support to obtain the hotfix.

Note If additional issues occur or if any troubleshooting is required, you might have to create a separate service request. The usual support costs will apply to additional support questions and issues that do not qualify for this specific hotfix. For a complete list of Microsoft Customer Service and Support telephone numbers or to create a separate service request, go to the following Microsoft website:.

If you do not see your language, it is because a hotfix is not available for that language. Then, use the. The English version of this hotfix has the file attributes or later file attributes that are listed in the following table. When you view the file information, it is converted to local time. The AcquireConnection method call to the connection manager "Excel Connection Manager" failed with error code 0xC Pipeline: Excel Source failed validation and returned error code 0xCC.

The solution is to run your package in 32bit mode. This solution will also allow you to debug a Script Task, because that also doesn't work in 64bit mode. Setting it will affect all packages within the project. Go to the Debugging pane and select false under Run64bitRuntime. Go to the Execution Options pane and check "Use 32 bit runtime". SSMS - Use 32 bit runtime 32 bit problems Besides running 64 bit problems there are also 32 bit problems.

For example, Fuzzy Lookup will not run in 32 bit. The solution for that is to run in 64 bit mode. So running an Excel source and a Fuzzy Lookup within the same package could be a bit of a challenge.

EXE Note : For 32bit execution via dtexec. Unknown 8 October at Joost van Rossum 8 October at Anonymous 30 November at



0コメント

  • 1000 / 1000